Cassette Air Conditioner (FCMF/FCVF-A)

SKU: FCMF/FCVF-A Category:

Specification

New Round Flow Cassette (Cooling Only)

Model Indoor unit FCMF50ARV16 FCMF71ARV16 FCMF90ARV16 FCMF100ARV16
Outdoor unit RZMF50BRV16 RZMF71BRV16 RZMF90BRV16 RZMF100BRV16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code Standard Without Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.0 (3.2 ~5.6) 7.1 (3.2 ~8.0) 9.0 (4.5 ~10.1) 10.0 (5.0 ~11.2)
Power consumption Cooling-Rated kW 1.27 1.90 2.42 2.91
Annual Power Consumption kWh 744.87 1057.11 1365.2 1665.15
ISEER / Stars Wh/Wh 5.2 5.2 5.1 4.65

Indoor unit

Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 22 25
Panel kg 5.5
Colour Ivory White

Outdoor unit

Compressor Type Hermetically Sealed Swing Type
Motor output kW 1.3 1.3 1.6 1.6
Refrigerant R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length m 30 30 50 50
Max. installation level difference m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

New Round Flow Cassette (Cooling Only)

Model Indoor unit FCMF125ARV16 FCMF125ARV16 FCMF140ARV16 FCMF140ARV16
Outdoor unit RZMF125BRV16 RZMF125BRY16 RZMF140BRV16 RZMF140BRY16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code Standard Without Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7 ~14.0) 12.5 (5.7 ~14.0) 14.0 (6.2 ~15.5) 14.0 (6.2 ~15.5)
Power consumption Cooling-Rated kW 4.60 4.225 5.80 5.30
Annual Power Consumption kWh NA
ISEER / Stars Wh/Wh NA

Indoor unit

Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5 / 33 / 29 / 25 / 21
cfm 1288/1165/1024/883/742
Sound level (H/HM/M/ML/L) dB(A) 46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 25
Panel kg 5.5
Colour Ivory White

Outdoor unit

Compressor Type Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length m 50 50 50 50
Max. installation level difference m 30 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

Model Indoor unit FCVF50ARV16 FCVF71ARV16 FCVF90ARV16 FCVF100ARV16
Outdoor unit RZVF50BRV16 RZVF71BRV16 RZVF90BRV16 RZVF100BRV16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code Without Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.0 (3.2 ~ 5.6) 7.1 (3.2 ~8.0) 9.0 (4.5 ~10.1) 10.0 (5.0 ~11.2)
Power consumption Cooling-Rated kW 1.52 2.235 2.58 3.16
Annual Power Consumption kWh 889.62 1264.11 1565.65 1839.63
ISEER / Stars Wh/Wh 4.35 4.35 4.45 4.21

Indoor unit

Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 22 25
Panel kg 5.5
Colour Ivory White

Outdoor unit

Compressor Type Hermetically Sealed Swing Type
Motor output kW 1.3 1.3 1.6 1.6
Refrigerant R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length m 30 30 50 50
Max. installation level difference m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

Model Indoor unit FCVF125ARV16 FCVF125ARV16 FCVF140ARV16 FCVF140ARV16
Outdoor unit RZVF125BRV16 RZVF125BRY16 RZVF140BRV16 RZVF140BRY16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code Standard Without Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7 ~14.0) 12.5 (5.7 ~14.0) 14.0 (6.2 ~15.5) 14.0 (6.2 ~15.5)
Power consumption Cooling-Rated kW 4.70 4.35 5.90 5.50
Annual Power Consumption kWh NA
ISEER / Stars Wh/Wh NA

Indoor unit

Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5 / 33 / 29 / 25 / 21
cfm 1288/1165/1024/883/742
Sound level (H/HM/M/ML/L) dB(A) 46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 25
Panel kg 5.5
Colour Ivory White

Outdoor unit

Compressor Type Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length m 50 50 50 50
Max. installation level difference m 30 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.